Healthcare Business Review

Advertise

with us

  • Europe
    • US
    • EUROPE
    • APAC
    • CANADA
    • LATAM
  • Home
  • Sections
    Business Process Outsourcing
    Compliance & Risk Management
    Consulting Service
    Facility Management Services
    Financial Services
    Healthcare Construction
    Healthcare Education
    Healthcare Marketing
    Healthcare Procurement
    Healthcare Staffing
    Medical Transcription and Translation
    Medical Transportation
    Psychological Services
    Radiology
    Therapy Services
    Waste Management
    Business Process Outsourcing
    Compliance & Risk Management
    Consulting Service
    Facility Management Services
    Financial Services
    Healthcare Construction
    Healthcare Education
    Healthcare Marketing
    Healthcare Procurement
    Healthcare Staffing
    Medical Transcription and Translation
    Medical Transportation
    Psychological Services
    Radiology
    Therapy Services
    Waste Management
  • CXO Insights
  • News
  • Vendor Viewpoint
  • Conferences
  • CXO Awards
×
#

Healthcare Business Review Weekly Brief

Be first to read the latest tech news, Industry Leader's Insights, and CIO interviews of medium and large enterprises exclusively from Healthcare Business Review

Subscribe

loading

Thank you for Subscribing to Healthcare Business Review Weekly Brief

  • Home
  • CXO Insights

The need of the Hour: Patient safety

Healthcare Business Review

Mark Meyers, Associate Vice President of Performance Improvement and Healthcare Informatics, Temple Health – Temple University Health System
Tweet

Alarm fatigue is a multifaceted problem that can lead to patient injury up to and including death. Reducing the number of non-actionable alarms improves opportunities for clinicians to respond to truly actionable alarms. Nursing leaders should work to provide care environments that produce meaningful information to monitor technicians to provide safe care. Careful consideration to reduce alarms to make them meaningful is the key to success to provide a safe and effective care environment.


Patient safety literature supports that alarm management deficiencies are mostly caused by human errors that relate to system complexities. The circumstances of alarm management systems are usually institutionally unique and are influenced by organizational culture, equipment, and styles of alarm management. Variability across care systems and within department units contributes to troubling problems that cannot be solved with a single, broad approach. Telemetry rooms can be an effective strategy to combat alarm management challenges; however, the design and set up of these rooms can expose telemetry technicians, also known as monitor watchers, to a barrage of alarms that may be overwhelming and lead to patient safety events.


A good portion of the available research discusses the utilization of several techniques to reduce the alarming burden that leads to alarm fatigue. These techniques such as, proper lead placement and maintenance or customizing alarm limits to meet a patient’s clinical condition. While all of these methods have proven to reduce alarm fatigue and decrease non[1]actionable alarms, they all rely on end[1]user intervention.


Eliminating premature ventricular contractions (PVC) alarms from telemetry monitoring reduces non-actionable alarms and requires no end-user intervention. The PVC alarms are non[1]actionable alarms that were addressed in the early days of physiologic monitoring but have little to no value in today’s telemetry monitoring. These alerts are frequent and intrusive to be able to hear actionable alarms.


Biomedical engineering removed the three PVC alarms (Multiform PVC, Pair PVC, and Run PVC). 


Eliminating the aforementioned PVC alarms showed an overall decrease in the number of alarms and an increase in the percentage of actionable alarms to which telemetry technicians are exposed. This reduction in overall alarms begins to promote an environment that will have fewer alarms not only for telemetry but for each of the clinical floors that the telemetry rooms support. Continual work to reduce non-actionable alarms will provide clinicians with the ability to appropriately respond and promote a safer and quieter patient environment.


Patient Safety Literature Supports that Alarm Management Deficiencies are Mostly Caused by Human Errors that Relate to System Complexities.

  


Turning off the non-actionable multiform PVC, pair PVC, and run PVC alarms, eliminating the need for the telemetry technicians or nurses to do anything. The alarms are off. Other interventions, such as proper lead placement and maintenance, customizing alarm limits to meet a patient’s clinical condition, take many nurses or telemetry technicians to perform a similar task regularly to ensure that alarms are reduced. This is not to say that these interventions are not good ideas, but two clinicians could have different views about how to modify alarm settings, even after they receive the same education. Eliminating the PVC alarms did not need to have any workflow changes for the telemetry technicians or nurses and was consistent.


The change was effective in reducing the overall number of alarms in the telemetry room. While the number of actionable alarms increased, it was not at a statistically significant level. The feeling of the telemetry technician’s attitude toward their ability to respond to alarms improved during this process. This type of project should be considered as a primary method of alarm management because of the ease of implementation and that there is no impact to the workflow of the telemetry technicians.


Weekly Brief

loading
> <
  • Current Issue
  • Current Issue
  • Current Issue

Read Also

Intensive Care Medicine -The Original Tech Disruptor in Healthcare

Intensive Care Medicine -The Original Tech Disruptor in Healthcare

Mainak Majumdar, Director, Intensive Care Services, Mercy Health Australia
READ MORE
Emerging Diagnostic Technologies in Healthcare

Emerging Diagnostic Technologies in Healthcare

Winny Xie, Molecular Predictive & Diagnostic Lab Head, PT Prodia Widyahusada Tbk
READ MORE
Transforming the Back Office of P2P

Transforming the Back Office of P2P

Misty Garrison, Director of Procurement Operations, UVA Health
READ MORE
The CEO's Playbook for Modern Hospital Management

The CEO's Playbook for Modern Hospital Management

Ts. Dr. James Chong, Chief Executive Officer, Columbia Asia Hospital
READ MORE
Leading Case Management Through Communication and Systems Thinking

Leading Case Management Through Communication and Systems Thinking

Alison Boone, MSRN, CCM, Director of Case Management, Mass General Brigham
READ MORE
Creating a Culture of Trust and Accountability in Medication Safety

Creating a Culture of Trust and Accountability in Medication Safety

Ambrosia Johnson, System Manager, Pharmacy Medication Safety, CommonSpirit Health
READ MORE

Leading Case Management Through Communication and Systems Thinking

Alison Boone, MSRN, CCM, Director of Case Management, Mass General Brigham

Creating a Culture of Trust and Accountability in Medication Safety

Ambrosia Johnson, System Manager, Pharmacy Medication Safety, CommonSpirit Health

National Proton Center Opens in Collaboration with Children's National Hospital

Jeffrey Dome, Senior Vice President, Children’s National Hospital

Delivering Growth, Collaboration and Innovation Tactics for Nursing

Imana Mo Minard, Director of Nursing, Corewell Health
Loading...
Copyright © 2026 Healthcare Business Review. All rights reserved. |  Subscribe |  Sitemap |  About us |  Newsletter |  Feedback Policy |  Editorial Policy follow on linkedin
CLOSE

Specials

I agree We use cookies on this website to enhance your user experience. By clicking any link on this page you are giving your consent for us to set cookies. More info

This content is copyright protected

However, if you would like to share the information in this article, you may use the link below:

https://www.healthcarebusinessrevieweurope.com/cxoinsight/the-need-of-the-hour-patient-safety-nwid-1239.html